Part Number Hot Search : 
MEW1031 39162 C1470 K1120DA OM6019SA MPX4200 OPF50014 0502N
Product Description
Full Text Search
 

To Download MLX90601B Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Datasheet Analog IR thermometer module
MLX90601B
Features
* * * * * * Remote temperature measurement Fully linearised signals Analog voltage output Factory calibrated EEprom ECC Open drain relay driver output
Applications
* * * * Automotive climate control Toasters, microwave ovens and other appliances that require temperature control Residential, commercial climate control and occupancy detection Industrial temperature transducer and monitoring applications
Ordering Information
M L X 9 0 6 0 1 E Z A B X X
Product Code
Temperature Suffix Package Suffix
Type
Version
Supply, i/o-Configuration and temperature ranges B C D Analog voltage output SPI serial interface PWM output
Part No MLX90601 MLX90601
Temperature E E
Suffix Package ZA ZA
Type B B
Version AA BA
Description 8 bit Analog -20/120C 5V supply 8 bit Analog 5/60C 5V supply
Functional Diagram
IR+ IRRsens VSS IRINP IRINN TINP IROUT TINN R1D C6 IROUT VDD C3 5V
Description
The MLX90601B is a versatile IR thermometer module, which performs signal conditioning, linearisation and ambient temperature compensation. The module is built around the MLX90313 IR sensor interface, which uses high performance chopper stabilized amplifiers, providing excellent noise performance. The sensing element is the MLX90247 discrete IR thermopile. The module is delivered factory calibrated. The output is an absolute analog voltage output for both sensor ambient temperature and the object temperature. The REL1 output is the open drain relay driver output available in MLX90313.
MLX90247
TEMPOUT
TEMPOUT R1C C7
MLX90313
CREF R3 REL1 VSS
REL1
VSS/GND
390109060101 Rev. 004
Page 1 of 8
Dec/01
Datasheet Analog IR thermometer module
MLX90601B
ELECTRICAL CHARACTERISTICS Parameter Symbol Test Condition
VDD @ Ta=25C f 100kHz rms-value 8 IROUT IROUT IROUT IROUT IROUT 500 f 100kHz rms-value 15 TEMPOUT TEMPOUT TEMPOUT TEMPOUT 0 1 20 500 32 10 Vdd-0.2 75 400 0 1 20 Vdd-0.2
Min
4.5 1.1 75
Typ
5 5 1.3
Max
6 5.6 1.5
Unit
V mA V dB
Regulator and consumption Supply voltage range Vin Supply current Idd POR threshold voltage Vpor IR-chain amplifier and output driver Power supply rejection PSSR ratio Input referred white noise Vnir Chopper frequency fc Output voltage range Output source current Iod Output sink current Ios DC Output impedance, rod drive DC Output impedance, ros sink Amplifier bandwidth BW Temp-chain amplifier and output driver Power supply rejection PSSR ratio Input referred white noise Vntemp Chopper frequency fc Output voltage range ORtemp Output source current Iod Output sink current Ios AC Output impedance ro Amplifier bandwidth BW Rel1 open drain relay driver High voltage protections output impedance Ro ADC Resolution Monotonicity Differential non-linearity DNL Integral non-linearity INL Gain error Total input-referred noise DAC Resolution Monotonicity Differential non-linearity Integral non-linearity
25
10 100
nV/Hz kHz V mA uA Hz dB nV/Hz kHz V mA uA Hz V
100
full scale Vref=3V
12 bit guaranteed by design 0.4 LSB 1/2 LSB 1 LSB 0.2 LSB
DNL INL
8 bit guaranteed by design 1/2 LSB 1/2 LSB
390109060101 Rev. 004
Page 2 of 8
Dec/01
Datasheet Analog IR thermometer module
MLX90601B
General Description
MLX90601 is a versatile IR thermometer built around the MLX90247 Discrete IR thermopile sensor with on-chip PTC and the MLX90313 Programmable IR sensor interface. MLX90313 amplifies the signals coming from MLX90247 and converts them to digital by means of two high performance, low noise, chopper stabilized amplifiers and the 12-bit analog to digital converter. The digital unit on the interface then performs the ambient compensation of the IR signal. This results in two temperature signals, one representing the temperature of the object the IR sensor is pointed at (Tobject) and one representing the temperature of the sensor (Tambient). Both signals are then linearised and presented at the outputs (Tobject is present at pin IROUT, Tambient is present at pin TEMPOUT) by means of the 8 bit digital to analog converter. The REL1 output is directly connected to the open drain relay driver output of MLX90313. This output is switched by means of a factory programmable comparator.
Absolute Maximum Ratings
Supply Voltage, VDD (overvoltage) Supply Voltage, VDD (operating) Reverse Voltage Protection Supply Current, IDD @25C Output Current, IOUT Operating Temperature Range, TA Storage Temperature Range, TS ESD Sensitivity 80V 4.5V - 6V -5V 6 mA mA -40C - 125C -55C - 150C 4kV
Pinout
Pin 1 2 3 4 5 Symbol IROUT TEMPOUT VDD REL1 VSS Description Object temperature output Ambient temperature output Supply pin Open drain, relay driver comparator output Ground
Unique Features
MLX90601 is an automotive grade IR thermometer that can be fitted to any contactless temperature measurement application by means of the programmable interface. The module is designed to cope with all standard qualification tests oriented towards the harsh automotive environment. If so desired, all temperature ranges and comparator settings can be adapted to the application. MLX90601 is delivered calibrated, relieving the customer of IR calibration.
390109060101 Rev. 004
Page 3 of 8
Dec/01
Datasheet Analog IR thermometer module
MLX90601B
Detailed Description Analog Features
Supply The module should be supplied directly with a nominal 5V regulated supply on pin VDD. (4.5V - 6V) The power-on reset circuitry is internal to MLX90313. The module is fully operational 16 ms from the time the supply crosses 1.3V. The POR circuit will issue another reset if the supply voltage goes below 1.3V.
Linearisation proceeds in two steps. In the first step the ambient temperature is calculated from the measured signal coming from the on-chip PTC temperature sensor of MLX90247. The value is stored in a dedicated register, controlling the output electronics. In the second step the value of the ambient temperature is combined with the measured signal coming from the IR thermopile sensor inside MLX90247 to obtain a calculated value for the object temperature, based on the calibration data. The value is stored in a dedicated register and from there available for the output electronics. Note that on request any arbitrary linearisation curve can programmed. A very wide range of applications can be covered by MLX90601 family.
A/D The MLX90313 on the module contains a 12-bit analog to digital converter. True 12-bit conversion is achieved by a fully differential analog part of the converter. Automatic calibration is implemented in the background, which allows precise conversion in a very wide temperature range.
Sensor Characteristics
For detailed specification we refer to the datasheet on MLX90247, available from the Melexis website. In a calibrated module the linearisation unit of MLX90313 takes all characteristics of the sensor into account, including all process variations they are subject to. The TO-39 sensor housing of the thermopile has a 2.5mm diameter aperture, resulting in a 70 full angle field of view. The silicon filter used as IR-window is treated with an antireflective coating that will pass minimum 75% of IR radiation in the wave length band from 7.5m to 13.5m. Below 5m, 99.5% of incoming radiation is reflected by the filter.
D/A An 8-bit digital to analog converter is used to output the data for the linearised Tobject- and Tambient signals.
Output drivers The IROUT and TEMPOUT pin drivers can source 1mA and sink 20A and are reverse voltage protected down to -5V relative to VSS. REL1 is an open drain relay driver output controlled by the comparator circuitry of MLX90313. The digital comparator's threshold (25C) and hysteresis (2C) are preset from factory. The comparator uses Tobject as input signal.
Pin Descriptions
IROUT IRout analog voltage output pin. The voltage at this pin is a linear representation of Tobject, the temperature of the object the IR sensor is pointed at. The driver can source at least 1mA and sink at least 20A to/from an external load.
Linearisation Unit
The linearisation unit of MLX90313 realizes 3 functions: 1. Offset measurement and calibration (offset drift compensation) 2. Measurement and offset cancellation 3. Linearisation. 390109060101 Rev. 004
TEMPOUT Tempout analog voltage output pin. The voltage Page 4 of 8 Dec/01
Datasheet Analog IR thermometer module
at this pin is a linear representation of Tambient, the temperature of the IR sensor, as measured by the PTC inside MLX90247. The driver can source at least 1mA and sink at least 20A to/from an external load. The comparator is a digital comparator, with a resolution of 12 bits. By default the input polarity is inverting. Threshold and hyteresis values are version dependent, as indicated below. These settings can be changed by factory programming on request. default REL1 settings Version Threshold Hysteresis 5/60C version 25C 2C -20/120C version 50C 5C VSS: Supply pin
MLX90601B
VDD: Supply pin
REL1 Open drain relay driver output. The typical onresistance of this driver is <10 with a supply voltage of VDD=5V.
REL1 Tobject
COMP
Threshold in EEPROM VSS Hysteresis in EEPROM
390109060101 Rev. 004
Page 5 of 8
Dec/01
Datasheet Analog IR thermometer module
MLX90601B
Applications Information
Connection of the MLX90601 module into an application is straightforward. The 5V regulated supply should be connected between pin 3 (VDD) and pin 5 (VSS). The outputs can be measured relative to VSS at pin 1 (IROUT) for Tobject and pin 2 (TEMPOUT) for Tambient, e.g. by means of a voltmeter. In an actual application the module outputs can be directly connected to the A/D inputs of a microcontroller, e.g. as a replacement for a conventional temperature sensor. In many applications, the ambient temperature of the sensor is not needed. In this case, pin 2 can simply be left open. The REL1 signal at pin 4 can be used as input for a digital I/O or to drive a relay (not shown).
IR sensor MLX90313
Ta
IR+ IR-
IRINP IRINN TINP TINN
OPA OPA A/D D/A
TEMPOUT
2
Application Microcontroller A/D input (optional)
Thermisto r
Rsens VSS
Digital
To A/D D/A Ta
IROUT
1 A/D input
MLX90247
12 COMP
REL1
4 Digital input
EEprom, Control and Support Blocks CREF VDD
3 5V 5 VSS
VSS
MLX90601B
Output waveforms
IROUT output voltage versus Object Temperature
4.5 4
MLX90601EZA BBA
TEMPOUT output voltage versus Ambient Temperature MLX90601EZA BBA
4.5 4
Output Voltage IROUT (V)
3.5 3 2.5 2 1.5 1 0.5 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65
Output Voltage TEMPOUT (V)
3.5 3 2.5 2 1.5 1 0.5 0 -5 0 5 10 15 20 25 30 35 40 45 50 55 60
Object Temperature To (degC)
Ambient Temperature Ta (degC)
390109060101 Rev. 004
Page 6 of 8
Dec/01
Datasheet Analog IR thermometer module
Glossary of Terms ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD). Always observe Electro Static Discharge control procedures whenever handling semiconductor products. ADC: Analog to Digital Converter Ambient Compensation: The IR signal captured by a thermopile sensor is not only dependent on the temperature of the object (Tobject) but also on the temperature of the sensor itself. Therefore the IR signal is compensated for this effect by means of the measured sensor temperature (Tambient). This rather complex calculation is performed in the linearisation unit of MLX90313. Chopper Amplifier: Special amplifier configuration aimed at ultra low offset. DAC: Digital to Analog Converter. EEprom: Non-volatile memory that can be electrically erased and rewritten. This type of memory is used to store configuration and calibration data for the module. ECC: Error Checking and Correction. The EEprom on board of MLX90313 is equipped with a checking and correction feature based on the Hamming Code method. IR: Infrared. Every object emits infrared radiation in relation to its temperature. This effect can be used to measure this temperature without the need for physical contact. Linearisation: The signal from a thermopile is not linear with the object temperature. MLX90313 is therefore equipped with a digital calculation unit that produces an output that is linear with the object temperature. POR: Power-on reset: Reset circuit that starts the digital system in a known state whenever the supply voltage is cycled PSSR: Power Supply Rejection Ratio: Measure for an amplifier's immunity to disturbances on the supply connections. PTC: See Thermistor Ta, Tambient: The temperature of the IR sensor. Target: or Object: The object the IR module is aimed at. Thermistor: Temperature dependant resistor. Basically there are 2 types. The types that increase their resistance with rising temperature are PTC (positive thermal coefficient) type. The ones that decrease their resistance with rising temperature we call NTC (negative thermal coefficient) type. The MLX90313 can work with both types. The MLX90601 modules are equipped with sensors that use PTCs. To, Tobject: The temperature of the object one wishes to measure with the module Dec/01
MLX90601B
FAQ
Q: What is the accuracy? A: For an object temperature range between 5C and 60C the accuracy of measurement is 1C. For the wider object temperature range version (-20C/120C) the accuracy of measurement is 2C. Q: What is FOV? A: The FOV or Field Of View is a definition of the area the sensor is `seeing'. The sensor will detect radiation coming in at angles, relative to the sensor's central axis, from 0 to 35C. The full viewing angle is thus 70. Q: What is the useful temperature range? A: There are two temperature ranges of interest; the temperature of the object (or target), which you are trying to measure and the temperature of the sensor. The sensor temperature, called Tambient, should be between 0C and 50C. Outside this range the ambient temperature compensation will no longer work and calculation of the object's temperature will no longer be correct. The TEMPOUT output will saturate under this condition. The object temperature, called Tobject, should be between 5C and 60C. (-20C/120C for wide range version) Outside this range the IROUT output will saturate. Q: Can the temperature ranges be changed? A: Yes, MLX90313 is a programmable device. Melexis selected a limited set of standard ranges that will fit the majority of applications in order to limit delivery times. However, if necessary, the ranges can be adapted for any particular application. Contact your sales representative for more information.
390109060101 Rev. 004
Page 7 of 8
Datasheet Analog IR thermometer module
Disclaimer
Melexis reserves the right to periodically make modifications to product specifications. The information included herein is believed to be accurate and reliable. However, Melexis assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties, which may result from its use.
MLX90601B
Physical Characteristics
For the latest version of this document, go to our website at:
www.melexis.com
Or for additional information contact Melexis Direct:
Europe and Japan:
Phone: +32 13 61 16 31 E-mail: sales_europe@melexis.com
All other locations:
Phone: +1 603 223 2362 E-mail: sales_usa@melexis.com
390109060101 Rev. 004
Page 8 of 8
Dec/01


▲Up To Search▲   

 